Heater Sizing Chart for 7 hour heating period per 24 hours with floating solar cover
(If floating solar blanket not used increase heater size by 50%)
Heater Size
Metric
24°C
27°C
30°C
M²
M³
M²
M³
M²
M³
3Kw
6
8
5
7
4
5
6kW
12
16
10
13
8
11
7.5kW
15
21
12
16
10
13
9kW
18
25
14
20
12
16
12kW
24
33
19
26
15
21
15kW
30
41
24
33
19
27
18kW
36
49
29
39
23
32
21kW
42
58
34
46
27
37
24kW
48
66
38
53
31
42
30kW
60
82
48
66
39
53
36kW
72
99
58
79
46
64
48kW
96
132
77
105
62
85
60kW
120
165
96
132
77
106
72kW
144
197
115
158
93
127
84kW
168
230
134
184
108
149
96kW
192
263
154
210
124
170
108kW
216
296
173
237
139
191
120kW
240
329
192
263
155
212
Model Ref
Imperial
75°F
80°F
85°F
SQ.FT.
GALLS.
SQ.FT.
GALLS.
SQ.FT.
GALLS.
12PHR/3
63
1750
50
1400
42
1170
12PHR/6
125
3500
100
2800
83
2340
12PHR/7.5
156
4370
125
3500
104
2920
12PHR/9
188
5250
150
4200
125
3500
12PHR/12
250
7000
200
5600
167
4670
24PHR/15
313
8750
250
7000
208
5840
24PHR/18
375
10500
300
8400
250
7000
24PHR/21
438
12250
350
9800
292
8170
24PHR/24
500
14000
400
11200
334
9340
36PHR/30
625
17500
500
14000
417
11670
36PHR/36
750
21000
600
16800
500
14000
72PHR/48
1000
28000
800
22400
667
18680
72PHR/60
1250
35000
1000
28000
834
23350
72PHR/72
1500
42000
1200
33600
1001
28020
120PHR/84
1750
49000
1400
39200
1167
32680
120PHR/96
2000
56000
1600
44800
1334
37350
120PHR/108
2250
63000
1800
50400
1501
42020
120PHR/120
2500
70000
2000
56000
1668
46690
The sizing chart is for outdoor pools in the
South of England, running from the beginning of May until the
end of september. For pools in the North, multiply the heater
size by 1.3 - 1.5 depending on the exposure of the pool.
The figures shown for capacity of the pool - in gallons or M³
- are based upon an average depth of 4'6" (1.36m) and are
provided as a guide when exact surface area is not known.
For indoor pools, provided the air temperature is maintained
at least 1°C above the pool temperature by an alternative
form of heating 24 hours per day, the heater size may be reduced
by multiplying by 0.7, but since running costs are related to
the size of the pool and the temperature required, not the size
of the heater, we advise keeping to the table where possible.
In countries where off-peak electricity is not available, heaters
sized at 1kW per 1000 gallons (4500 litres) with the heater
operating 24 hours per day, will normally be adequate and will
give an 8°F (4.4°C) rise in 24 hours assuming no losses.
Thermalec Products. a division of Meddings Thermalec Ltd a company registered in England and Wales at:- Kingsley Close, East Way, Lee Mill Industrial Estate, Ivybridge, Devon, PL21 9LL Telephone: 01752 313343, Fax: 01752 313353, Email: info@thermalec.co.uk. Registration No.: 950992. VAT: 207 8137 69